We use cookies to ensure that we give you the best experience on our website. If you click 'Accept all cookies' we'll assume that you are happy to receive all cookies and you won't see this message again. If you click 'Reject all non-essential cookies' only necessary cookies providing core functionality such as security, network management, and accessibility will be enabled. Click 'Find out more' for information on how to change your cookie settings.

We investigated aortic valve hemodynamic performance and perioperative left ventricular function in 50 patients (mean [+/- SD] age, 64 +/- 9 years; 34 men, 16 women) undergoing elective aortic valve replacement, using an aortic homograft (n = 20), a Toronto stentless porcine valve (n = 20), or a stented bioprosthesis (n = 10), by transesophageal echocardiography combined with high-fidelity cavity pressure recordings and thermodilution cardiac output measurements. Thirty-nine patients had aortic stenosis; 11 had predominant regurgitation. Thirteen patients with concomitant coronary artery stenosis underwent grafting. Left ventricular mass index in all patients was 280 +/- 110 g/m2. The transvalvular pressure drop and energy consumption were significantly higher with stented than stentless valves (5 with aortic homograft and 11 with Toronto valve, with matched age and valve size; 20 +/- 12 versus 3 +/- 9 mm Hg; 21% +/- 13% versus 8% +/- 8%, both p < 0.01). However, there was no difference in these variables between the Toronto valve and the aortic homograft (3 +/- 12 versus 2 +/- 10 mm Hg; 5% +/- 14% versus 2% +/- 12%, both p > 0.05), although the Toronto valves (normalized to body surface area) were larger than the aortic homografts (14.4 +/- 1.9 versus 12.6 +/- 1.8 mm/m2, p < 0.01). There was no significant difference in left ventricular stroke volume index or stroke work index in the systemic circulation, either between stentless and stented valves or between aortic homografts and Toronto valves, although the cross-clamp time required to insert a stentless valve was 20 minutes longer than that for a stented valve.(ABSTRACT TRUNCATED AT 250 WORDS)

Type

Journal article

Journal

Ann Thorac Surg

Publication Date

08/1995

Volume

60

Pages

S395 - S401

Keywords

Aged, Aged, 80 and over, Aortic Valve, Aortic Valve Insufficiency, Aortic Valve Stenosis, Bioprosthesis, Echocardiography, Transesophageal, Female, Heart Valve Prosthesis, Hemodynamics, Humans, Male, Middle Aged, Stents, Stroke Volume, Thermodilution, Ventricular Function, Left