We use cookies to ensure that we give you the best experience on our website. If you click 'Accept all cookies' we'll assume that you are happy to receive all cookies and you won't see this message again. If you click 'Reject all non-essential cookies' only necessary cookies providing core functionality such as security, network management, and accessibility will be enabled. Click 'Find out more' for information on how to change your cookie settings.

INTRODUCTION: Cardiac resynchronization therapy (CRT) using quadripolar left ventricular (LV) leads provides more pacing vectors compared to bipolar leads. This may avoid phrenic nerve stimulation (PNS) and allow optimal lead placement to maximize biventricular pacing. However, a long-term improvement in patient outcome has yet to be demonstrated. METHODS: A total of 721 consecutive patients with conventional CRTD criteria implanted with quadripolar (n = 357) or bipolar (n = 364) LV leads were enrolled into a registry at 3 UK centers. Lead performance and mortality was analyzed over a 5-year period. RESULTS: Patients receiving a quadripolar lead were of similar age and sex to those receiving a bipolar lead, although a lower proportion had ischemic heart disease (62.6% vs. 54.1%, P = 0.02). Both groups had similar rates of procedural success, although lead threshold, impedance, and procedural radiation dose were significantly lower in those receiving a quadripolar lead. PNS was more common in those with quadripolar leads (16.0% vs. 11.6%, P = 0.08), but was eliminated by switching pacing vector in all cases compared with 60% in the bipolar group (P < 0.001). Furthermore, LV lead displacement (1.7% vs. 4.6%, P = 0.03) and repositioning (2.0% vs. 5.2%, P = 0.03) occurred significantly less often in those with a quadripolar lead. All-cause mortality was also significantly lower in the quadripolar compared to bipolar lead group in univariate and multivariate analysis (13.2% vs. 22.5%, P < 0.001). CONCLUSIONS: In a large, multicenter experience, the use of quadripolar LV leads for CRT was associated with elimination of PNS and lower overall mortality. This has important implications for LV pacing lead choice.

Original publication

DOI

10.1111/jce.12625

Type

Journal article

Journal

J Cardiovasc Electrophysiol

Publication Date

05/2015

Volume

26

Pages

540 - 546

Keywords

cardiac resynchronization therapy, implantable cardioverter defibrillator, left ventricular pacing, phrenic nerve stimulation, quadripolar lead, Aged, Cardiac Resynchronization Therapy, Cardiac Resynchronization Therapy Devices, Cause of Death, Chi-Square Distribution, England, Equipment Design, Equipment Failure, Female, Heart Failure, Humans, Logistic Models, Male, Multivariate Analysis, Odds Ratio, Peripheral Nervous System Diseases, Phrenic Nerve, Registries, Risk Factors, Time Factors, Treatment Outcome, Ventricular Function, Left