We use cookies to ensure that we give you the best experience on our website. If you click 'Accept all cookies' we'll assume that you are happy to receive all cookies and you won't see this message again. If you click 'Reject all non-essential cookies' only necessary cookies providing core functionality such as security, network management, and accessibility will be enabled. Click 'Find out more' for information on how to change your cookie settings.

BACKGROUND: External stents inhibit saphenous vein graft (SVG) intimal hyperplasia in animal studies. We investigated whether external stenting inhibits SVG diffuse intimal hyperplasia 1 year after coronary artery bypass graft surgery. METHODS: Thirty patients with multivessel disease undergoing coronary artery bypass graft surgery were enrolled. In addition to an internal mammary artery graft, each patient received one external stent to a single SVG randomly allocated to either the right or left coronary territories; and one or more nonstented SVG served as the control. Graft patency was confirmed at the end of surgery in all patients. The primary endpoint was SVG intimal hyperplasia (mean area) assessed by intravascular ultrasonography at 1 year. Secondary endpoints were SVG failure, ectasia (>50% initial diameter), and overall uniformity as judged by Fitzgibbon classification. RESULTS: One-year follow-up angiography was completed in 29 patients (96.6%). All internal mammary artery grafts were patent. Overall SVG failure rates did not differ significantly between the two groups (30% stented versus 28.2% nonstented SVG, p = 0.55). The SVG mean intimal hyperplasia area, assessed in 43 SVGs, was significantly reduced in the stented group (4.37 ± 1.40 mm(2)) versus nonstented group (5.12 ± 1.35 mm(2), p = 0.04). In addition, stented SVGs demonstrated marginally significant improvement in lumen uniformity (p = 0.08) and less ectasia (6.7% versus 28.2%, p = 0.05). There was some evidence that ligation of side branches with metallic clips increased SVG failure in the stented group. CONCLUSIONS: External stenting has the potential to improve SVG lumen uniformity and reduce diffuse intimal hyperplasia 1 year after coronary artery bypass graft surgery.

Original publication

DOI

10.1016/j.athoracsur.2015.01.060

Type

Journal article

Journal

Ann Thorac Surg

Publication Date

06/2015

Volume

99

Pages

2039 - 2045

Keywords

Aged, Coronary Angiography, Coronary Artery Bypass, Coronary Artery Disease, Coronary Vessels, Female, Follow-Up Studies, Graft Occlusion, Vascular, Humans, Male, Mammary Arteries, Prospective Studies, Reoperation, Saphenous Vein, Stents, Treatment Outcome, Ultrasonography, Interventional, Vascular Patency